Pump and Valve Passivation: How to Treat Mixed Steel Parts

24

Nov

Pump and Valve Passivation: How to Treat Mixed Steel Parts

In brief: Pump and valve passivation is a chemical treatment that removes free iron (loose iron specks left by tools and machining) and other surface contamination from the stainless steel parts of pumps and valves and helps the chromium-rich passive layer form evenly. Many pumps and valves mix steel grades. The International Stainless Steel Forum says hardened martensitic grades are used for pump bodies, impellers and shafts, valve bodies and stems, and ASTM A351 covers austenitic (300 series) castings for valves, so many valve bodies are 300 series but either family is possible. In nitric acid, SSINA gives a lower temperature for 400 series steel (50°C) than for 300 series (65°C). From that, our advice is to passivate the two families in separate runs, with seals, gaskets and packing removed first where the unit can be stripped. A unit treated whole in place needs one product suited to all stainless grades. ASTM A967 requires passivated parts to show no etching, pitting or frosting. Rouging Solutions Pvt. Ltd., Ahmedabad, a distributor of CitriSurf citric acid passivation products, uses CitriSurf 2050 for 300 series parts, CitriSurf 2250 for 400 series parts and CitriSurf 77 Plus for on-site work, at its own premises or the customer's site, with all the relevant documents.

The pump casing looks fine after the shutdown clean. Two weeks later, the shaft next to it has brown spots. That pattern puzzles a lot of maintenance teams, and it often has a simple cause. The two parts are not made of the same steel, so they do not react to the same treatment in the same way.

Pump and valve passivation is the chemical clean that helps stainless steel pumps and valves resist rust after machining, repair or a long run. Many pumps and valves mix steel grades, so they need more care than a plain pipe. This guide shows which parts are usually which grade and why they go in separate baths. It also covers units that cannot be taken apart.

Key Takeaways

  • One pump or valve can hold 300 and 400 series steel.
  • Shafts, sleeves and stems are often hardened 400 series.
  • SSINA's nitric acid settings are 50°C for 400 series and 65°C for 300 series, so one setting rarely suits both.
  • Where you can strip a unit, sort parts by grade and remove the seals first.

What Is Pump and Valve Passivation?

Pump and valve passivation is a chemical treatment for the steel parts of pumps and valves. It removes free iron, the loose iron specks left by tools and machining, and other surface contamination. It also helps the passive layer, a thin film rich in chromium, to form evenly. A good layer helps the parts resist rust in service.

The main US standard for this work is ASTM A967. It covers "several different types of chemical passivation treatments for stainless steel parts". One of them is an immersion in citric acid. The standard also sets a clear goal for the finish. Passivated parts must "show no etching, pitting, or frosting" when you look at them.

Our passivation service uses citric acid products. Citric acid is one of the treatments A967 lists, and it is mild, which suits finished, machined parts like these.

Why Do Pumps and Valves Need Different Handling?

Many pumps and valves are built from more than one steel grade, and each grade wants its own settings. A valve body is often a softer 300 series steel. Shafts and stems are often a hardened 400 series grade that holds less chromium. Treat them all the same way, and one of them can end up worse off.

The reason is strength. A shaft has to take a heavy twisting load when the motor starts, so many makers pick hard steel for it. The International Stainless Steel Forum (ISSF) describes a pump maker that chose "AISI 420B grade for its high mechanical properties" for this reason. Hard steel gives you strength, but it pays for it with lower resistance to rust.

Seals, gaskets and packing are a third group, because they are not steel at all. They can trap acid, and some may swell or harden when they meet a chemical they were not made for. So a pump that looks like one part is really three groups of material.

Which Pump and Valve Parts Are Usually 300 Series or 400 Series?

Many valve bodies are cast 300 series, while shafts, sleeves and stems are often 400 series. Pump casings and impellers can be either. Makers differ, so check the material certificate for every part before you plan the job. Never guess the grade from the look of the steel, because 304 and 420 can look almost the same.

One pump can hold two steel families Check the material certificate for every part Often 300 series Often 400 series 300 or 400, check it Not steel Centrifugal pump Seal Shaft Sleeve (under seal) Casing Impeller Casing: 300 or 400 series, check it Impeller: 300 or 400 series, check it Shaft and sleeve: often 400 series Mechanical seal: take it out first Valve Stem: often 400 series Packing: take it out Body: often cast 300, check it Source: ISSF (400 series uses); ASTM A351 (cast 300 series bodies)

The ISSF guide to martensitic stainless steels says these hard grades "are used for pump bodies, impellers and shafts, valve bodies, stems". It gives one submersible pump where the shaft, impeller and sleeves "are made of AISI 420". Pump bodies and valve bodies are both on that list, so either can be 400 series.

Even so, many valve bodies are cast 300 series. ASTM A351 covers "austenitic steel castings for valves, flanges, fittings, and other pressure-containing parts". Most austenitic stainless steel is the 300 series family.

PartGrade you often findUsual treatment
Pump casing300 or 400 series, so check itMatch the product to the grade
ImpellerEither, so check itMatch the product to the grade
Shaft and sleeveHardened 400 series, such as 420CitriSurf 2250 for 400 series
Valve bodyOften cast 300 series, but check itMatch the product to the grade
Valve stem400 seriesCitriSurf 2250 for 400 series
Seals, gaskets, packingNot steelRemove before passivation

Can You Passivate 300 and 400 Series Parts in the Same Bath?

It is better not to. The two families want different settings, and a bath set for 300 series steel can be too harsh for a hardened 400 series shaft. Running them apart lets you match the product, time and temperature to each grade. It also keeps unlike metals from touching in the acid.

The settings really do differ. SSINA, the US stainless steel trade body, gives nitric acid settings on its passivation page. It suggests 65°C for 300 series steel but 50°C for the ferritic and martensitic 400 series grades. Ferritic grades, such as 430, are the 400 series steels that cannot be hardened. Citric acid is milder than nitric, and there are citric products made for the 400 series. At Rouging, we use CitriSurf 2050 for 300 series parts and CitriSurf 2250, a higher pH product, for the more sensitive 400 series.

Contact between parts matters too. SSINA's page on galvanic corrosion says it needs three things. It names "Two metals with different corrosion potentials", direct contact between them, and a liquid that connects them. A 420 shaft pressed into a 316 impeller and dipped in acid can tick all three boxes, at least while it is wet.

Our guide on how to choose a passivation chemical covers grade choice in more depth, including free-machining grades.

How to Do Pump and Valve Passivation, Step by Step

A good job follows the same order every time, from stripping the unit to the final test. Write each step down with the product, time and temperature you used. That record is what your QA team will ask for later, and it lets you repeat the job at the next shutdown.

  1. Strip the unit and split mixed parts. Take out the mechanical seal, O-rings, gaskets, packing and bearings. Pull the impeller and sleeves off the shaft, and tag each part so it goes back where it came from.
  2. Sort the steel parts into 300 series and 400 series piles, using the material certificates.
  3. Clean off oil and grease, since acid cannot reach steel under a film.
  4. Check for pits and scratches. Mechanical polishing or electropolishing can smooth rough spots before passivation. Worn valve seats need repair or a new part first.
  5. Passivate each group on its own, with CitriSurf 2050 for the 300 series and CitriSurf 2250 for the 400 series. In a tank with air blowers, use CitriSurf 3050 in place of 2050.
  6. Rinse well, with extra care at threads, keyways and blind holes.
  7. Dry fully, then test a sample part from each group before you rebuild.

Sometimes an impeller or sleeve is pressed on so tight that pulling it would damage the shaft. Then treat the shaft and the part together, with a product made for all stainless grades, such as CitriSurf 77 Plus. Keep the time short, rinse the joint well and check it closely afterwards. Two steels touching in acid is the galvanic risk described above.

Here is a made-up example to show the method. The scenario is fictional. A chemical plant near Dahej strips three process pumps and six valves during its April shutdown and sends us the steel parts. The certificates show 316 casings and bodies, with 420 shafts and stems. So the parts go through two runs, one for each grade, with the results filed against each tag number.

What If the Pump or Valve Cannot Be Taken Apart?

Then you have three choices. If the seals and soft parts can take the chemical, treat the unit whole in place. If they cannot, spray or wipe only the surfaces you can reach without wetting the seals. Or strip the unit after all. Ask the pump or seal maker which of these applies.

Strip it if you can, then sort by grade Can the unit be taken apart? Yes No Strip it and sort parts by grade Can the seals and soft parts take it? Ask the maker 300 series parts CitriSurf 2050 (3050 in air-blown tanks) 400 series parts CitriSurf 2250, own run Yes No Treat it whole, in place CitriSurf 77 Plus, for all grades Spray or wipe only the parts you can reach Or strip it after all Every route ends the same way Rinse, dry, test a sample and record it Source: Rouging Solutions

Pumps and valves often get treated in place when a whole line or loop is passivated. In pharma and food plants, that often means the sanitary pumps and valves on a CIP or WFI loop. They can be cleaned, derouged and passivated along with the pipes.

ASTM A380 covers cleaning and passivating "new stainless steel parts, assemblies, equipment, and installed systems". So installed systems are covered, but its scope is new equipment. For pumps already in service, agree the method and the acceptance test with your QA team before you start.

In place, every grade meets the same chemical, so the separate-run rule above cannot apply. Use a product made for all stainless grades. We use CitriSurf 77 Plus, which suits all stainless steel and is made for on-site work and large items. You get a little less control over the 400 series parts than a separate run gives, so check them closely afterwards.

A loop with pumps in it is a common case, and planning the drain points and hoses early saves a lot of time. Our guide to passivation shutdown planning covers that side of the job.

How Do You Check That the Passivation Worked?

Look first, then test a sample from each grade group. A sound part is clean, with no etching, pitting or frosting. ASTM A967 lists several tests, including the water immersion, high humidity, salt spray and copper sulfate tests. Pick one that suits the steel, because not every test suits every grade.

The copper sulfate test is the one to watch on hard parts. ASTM F1089 is written for surgical instruments, but its warning is useful here. It says the test "is not recommended for martensitic materials". It adds that these steels "may give a positive indication irrespective of the presence or absence" of surface contamination. So ask your QA team which test suits your 400 series parts.

Spots that come back after a short time are a sign that something went wrong. Common causes include dirt left under the acid, poor rinsing and the wrong product for the grade. Our guide to common passivation failures explains each one.

Where to Start

Remember this: a pump or valve is often made of more than one steel. The shaft and the casing can be two different grades. Where you can strip the unit, sort the parts by grade and remove the seals and gaskets before any acid touches them.

On Monday, pick one pump whose shaft keeps getting brown spots. Check its material certificate for the grade of each part. If the shaft is 400 series and was treated with the casing, you may have found your cause.

If you want help, our team can clean, passivate and test your pump and valve parts, at our premises or at your site. You get all the relevant documents and a reply within 24 hours.

Frequently Asked Questions

What is pump and valve passivation?

It is a chemical treatment that removes free iron and other surface contamination from the steel parts of pumps and valves. This helps the passive layer, a thin chromium-rich film, to form evenly. ASTM A967 covers the treatments, and one of them is a citric acid immersion.

Why does my pump shaft rust when the casing does not?

Do I need to remove the seals before passivation?

Can CitriSurf be used on 400 series valve stems?

Can a pump be passivated without taking it out of the line?

Rouging Solutions Editorial Team

The Rouging Solutions Editorial Team writes about passivation, derouging and industrial surface treatment for regulated industries. With 60+ combined years of experience across pharmaceutical, semiconductor and food processing sectors, we share technical insights backed by ASTM standards and real-world project data.

Sources. ASTM, A967/A967M-25, Chemical Passivation Treatments for Stainless Steel Parts (abstract and scope), for the citric acid treatment, the no etching, pitting or frosting finish and the list of tests · ASTM, A380/A380M-25, Cleaning, Descaling, and Passivation of Stainless Steel Parts, Equipment, and Systems (abstract), for new parts, assemblies and installed systems · ASTM, A351/A351M-18e1, Castings, Austenitic, for Pressure-Containing Parts (abstract), for austenitic castings for valves · ASTM, F1089-24, Corrosion of Surgical Instruments (scope), for the copper sulfate test on martensitic steel and the reason given · ISSF, Martensitic Stainless Steels, for the uses of martensitic grades in pump bodies, impellers, shafts, valve bodies and stems, and the AISI 420 and 420B examples · SSINA, Passivation, for the nitric acid temperatures by grade · SSINA, Galvanic Corrosion, for the three conditions it needs. Every quotation was read on the source on 19 November 2026. The chemical plant near Dahej is a fictional example. The parts diagram, the decision chart, the table and the seven-step list are ours.